MICROSET INSTRUMENTATION & CONTROLS
GST : 27AAWPR2850F1Z8

call images

Call us

08071779106

Change Language
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel
MS CT 9  - Conductivity TDS Indicating Controller Transmitter-Panel

MS CT 9 - Conductivity TDS Indicating Controller Transmitter-Panel

Price 21600 INR/ Piece

MOQ : 1 Piece

MS CT 9 - Conductivity TDS Indicating Controller Transmitter-Panel Specification

  • Frequency
  • 50/60 Hz
  • Rated Voltage
  • As per Model (Standard: 230 V AC, Optional: 24 V DC)
  • Efficiency
  • High Sensitivity and Stability (Microprocessor-based)
  • Output Voltage
  • 4-20 mA (Isolated Analog Output)
  • Input Current
  • Sensor Dependent (Signal Input: Conductivity/TDS Cell)
  • Mounting Type
  • Panel Mounting
  • Phase
  • Single Phase
  • Protection Level
  • IP65 (Front Panel)
  • Humidity
  • 0-95% RH, Non-condensing
  • Operating Temperature
  • 0C to 55C
  • Usage
  • Industrial Use
  • Condition
  • New
  • Function
  • Controller
  • Application
  • Conductivity and TDS Monitoring/Control in Water Treatment Plants, Industrial Processes, Effluent Treatment Plants (ETP), RO Plants, and Laboratories
  • Dimension (L*W*H)
  • 96 x 96 x 110 mm (Panel cutout 92 x 92 mm)
  • Power Mode
  • AC/DC Mains
  • Voltage
  • 90-270 VAC / 24 VDC
  • Power Consumption
  • 100~240 VAC 50/60Hz
  • Battery Life
  • Not Applicable (Mains Powered)
  • Accessories
  • User Manual, Mounting Screws
  • Transmitter Output
  • Isolated 4-20 mA Output for PLC/SCADA/BMS Integration
  • Sensor Compatibility
  • Works with 2-electrode and 4-electrode Conductivity/TDS Cells
  • Display
  • Alphanumeric, Large LCD Display with Backlight
  • Control Action
  • ON/OFF or Proportional Control (Selectable)
  • Relay Output
  • SPDT, 2 Nos. (Potential Free Contacts, Programmable Set-points)
  • Indication Range
  • Conductivity: 0.0 to 200.0 mS/cm (range-specific models available); TDS: as per calibration
  • Data Logging
  • Optional (Depends on Model Variant)
  • Panel Cutout
  • 92 x 92 mm
  • Enclosure Type
  • Weatherproof / Flameproof (Model Dependent)
  • Memory Retention
  • Non-volatile Memory for Data Storage
  • Calibration
  • Auto/Manual Calibration Facility
  • Alarm
  • Inbuilt Buzzer and Alarm Indications
 
 

MS CT 9 - Conductivity TDS Indicating Controller Transmitter-Panel About



Experience unrivaled value and reliability with the MS CT 9 Conductivity TDS Indicating Controller Transmitter-Panel. This decorated industrial device features a large, alphanumeric LCD display with backlight for terrific visibility, ensuring clear monitoring of conductivity and TDS levels. Tailored for seamless integration with PLC/SCADA/BMS, its isolated 4-20 mA output and programmable relay contacts maximize efficiency. Enjoy clearance pricing on models offering weatherproof or flameproof enclosures, unrivaled calibration flexibility, and non-volatile memory retention. Get robust performance ideal for water treatment, ETP, and industrial process applications across India.

Application & Advantages for Industrial Plants

The MS CT 9 Conductivity TDS Controller is used for precise water quality monitoring and control in water treatment plants, ETPs, RO units, and laboratory settings. Its main advantage is its adaptability, accommodating a wide conductivity range and providing both ON/OFF and proportional control actions. This ensures reliable operation and consistent results, supporting process optimization in industrial environments while maintaining plant safety and compliance standards with high sensitivity and stability.


Sample, Payment Terms & Export Markets

Order processing for the MS CT 9 is streamlined, with logistics ensuring timely delivery of sample units for evaluation. Flexible payment terms are available to suit customer needs. The main export markets include Asia, the Middle East, and Africa, with dedicated support for international shipping and documentation. Whether for bulk orders or single units, clients benefit from efficient logistics and clear communication throughout the entire ordering process, ensuring satisfaction from inquiry to delivery.


FAQ's of MS CT 9 - Conductivity TDS Indicating Controller Transmitter-Panel:


Q: How does the MS CT 9 controller integrate with existing PLC/SCADA/BMS systems?

A: The MS CT 9 controller provides an isolated 4-20 mA analog output, making integration with PLC, SCADA, or BMS seamless and straightforward. This allows live monitoring and control of conductivity and TDS parameters in real-time.

Q: What types of sensors are compatible with the MS CT 9 controller?

A: This controller is fully compatible with both 2-electrode and 4-electrode conductivity/TDS cells, offering flexibility for different industrial and laboratory setups.

Q: Where is the MS CT 9 Conductivity TDS Panel mainly used?

A: It is primarily used in water treatment plants, effluent treatment plants (ETP), RO plants, and laboratories, where precise monitoring and control of conductivity and TDS are required for efficient process management.

Q: What is the process for ordering a sample of the MS CT 9 controller?

A: Prospective buyers can request a sample through the supplier or manufacturer. Upon confirmation, logistics and delivery processes will ensure timely dispatch and order fulfillment with necessary documentation.

Q: What is the benefit of auto/manual calibration in the MS CT 9?

A: The dual calibration facility allows for easy and accurate calibration, either automatically or manually, enhancing measurement reliability and reducing maintenance effort.

Q: When does the built-in alarm system activate in the MS CT 9 Panel?

A: The inbuilt buzzer and alarm indicators are activated whenever conductivity or TDS levels exceed preset programmable set-points, providing immediate notification to operators.

Technical Details 

  • Principle : Two Electrode & Four Electrode
  • Display Range:
  • Conductivity : 0.00 to 500 mS/cm
  • Resistivity : 0.00.cm to 18.00M.cm
  • TDS : 0.00 to 250 g/L
  • Salinity : 700 ppt
  • Temp : -10 to 150C
  • Resolution : Conductivity: 0.01us/cm; 0.01ms/cm Resistivity: 0.01M.cm
  • TDS : 0.01mg/L Salinity: 0.01 ppt Temp: 0.1C
  • Accuracy : Conductivity: 0.5%F.S; Temp: 0.3C
  • Stability : 2%F.S
  • Temp Compensation : Automatic or manual (NTC 2.25K, NTC 10K,
  • Pt100, Pt 1000)
  • Relay Output : Two SPST relays, 3A 250VAC, 3A 30VDC
  • Communication : RS 485 MODBUS RTU
  • Signal Output : 0/4 to 20mA current
  • Configuration : Power failure protection, indefinite retention of Parameters
  • Display : 128 x 64 3.2-inch large graphic dot matrix LCD
  • Protection Grade : IP65
  • Enclosure Material : Enhanced ABS
  • Dimension : 98 x 98 x 130mm (Panel Cutout size 92x92mm)
  • Work Temperature : 0 to 60C, RH<95%, non-condensing
  • Storage Temperature : -10 to 60C, RH<55%, non-condensing
  • Electrical Interface : Reserve three M12 x 1.5 gland
  • Mounting : Panel & Field (both accessories included)
  • Power Supply : 85 to 265VAC,9 to 36VDC(Optional)
  • Weight : 0.6 kg
  • Power Consumption : < 3W

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Conductivity Category

MS CD 999 -Conductivity Sensor

MS CD 999 -Conductivity Sensor

Price 12600.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Consumption : Negligible (passive sensor) Volt (V)

Condition : New

MS CD 09 -Conductivity Indicating Controller Transmitter-Panel

MS CD 09 -Conductivity Indicating Controller Transmitter-Panel

Price 8100 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Power Consumption : 230V A.C +/10%, 50Hz Single Phase

Size : 96 x 96 x 65mm (Grey ABS Cabinet), 400grams for Inst. Only (Approx.)

MS CD TDS 18  - Conductivity TDS Indicating Controller - Panel

MS CD TDS 18 - Conductivity TDS Indicating Controller - Panel

Price 6300 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial USe

Power Consumption : 230V AC +/10%, 50Hz single phase

Size : 96 x 96 x 65mm (Grey ABS Cabinet)

MS CD 18-Conductivity Indicating Transmitter

MS CD 18-Conductivity Indicating Transmitter

Price 6300 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial USe

Power Consumption : 230V AC +/10%, 50Hz single phase

Size : 96 x 96 x 65mm (Grey ABS Cabinet)

Condition : New



Back to top